7. (Trained service technician only) Remove affected Processor and inspect Processor socket pins
for damaged or mis-aligned pins. If damage is found, or this is an upgrade Processor, replace
system board. If there are multiple Processor's, swap Processor's to move affected Procesor to
another Processor socket and retry. If problem follows the affected Processor (or there is only
one Processor), replace the affected Processor.
8. (Trained Service technician only) Replace the system board.
• S.68005 [S.68005] An error has been detected by the the IIO core logic on Bus %. The Global Fatal
Error Status register contains %. The Global Non-Fatal Error Status register contains %. Please
check error logs for the presence of additional downstream device error data.
Explanation: Critical IOH-PCI Error
Severity
Error
User Response
Complete the following steps:
1. Check log for a separate error for an associated PCIe device and service that error.
2. Check IBM support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
3. (Trained Service technician only) Replace the system board.
• S.680B8 [S.680B8] Internal QPI Link Failure Detected.
Explanation: Internal QPI Link Failure Detected
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this
error.
2. Inspect processor socket for foreign debris or damage. If debris is found remove debris.
3. If error recurs, or socket damage is found, replace the system board (Trained Service technician
only) .
4. (Trained Service Technician Only) Replace the processor.
• S.680B9 [S.680B9] External QPI Link Failure Detected.
Explanation: External QPI Link Failure Detected
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this
error.
2. Inspect processor socket for foreign debris or damage. If debris is found remove debris.
3. If error recurs, or socket damage is found, replace the system board (Trained Service technician
only) .
• W.11004 [W.11004] A processor within the system has failed the BIST.
Explanation: Processor Self Test Failure Detected
Severity
650
System x3300 M4 Installation and Service Guide