Lenovo x3300 M4 7382 Installation And Service Manual page 553

Hide thumbs Also See for x3300 M4 7382:
Table of Contents

Advertisement

No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
• 816f000d-040dffff : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 13)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d040dffff or 0x816f000d040dffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
• 816f000d-040effff : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 14)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d040effff or 0x816f000d040effff
Severity
Error
Serviceable
Yes
Appendix A. Integrated management module II (IMM2) error messages
541

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3300 m47382

Table of Contents