Lenovo x3300 M4 7382 Installation And Service Manual page 660

Hide thumbs Also See for x3300 M4 7382:
Table of Contents

Advertisement

1. Continue booting sytem. If system does not reset, manually reset the system.
2. If the error is not reported on the subsequent boot, no additional recovery action is required.
3. If the error persists, continue booting system and reflash UEFI image.
4. (Trained service technician only) Replace the system board.
• S.3818007 [S.3818007] The firmware image capsules for both flash banks could not be verified.
Explanation: CRTM image capsule could not be verified
Severity
Error
User Response
Complete the following steps:
1. If system failed to boot successfully, DC cycle system.
2. If system boots to F1 steup, flash UEFI image and reset bank to primary (if required). If system
boots without error, recovery is complete and no additional action is required.
3. If system fails to boot, or if flash attempt fails, (Trained service technician only) Replace the
system board.
• S.51003 [S.51003] An uncorrectable memory error was detected in DIMM slot % on rank %.
Explanation: [S.51003] An uncorrectable memory error was detected on processor % channel %. The
failing DIMM within the channel could not be determined.[S.51003] An uncorrectable memory error has
been detected during POST. Fatal Memory Error Occurred
Severity
Error
User Response
Complete the following steps:
1. If the node has recently been installed, moved, serviced, or upgraded, verify that the DIMM is
properly seated and visually verify that there is no foreign material in any DIMM connector on that
memory channel. If either of these conditions is found, correct and retry with the same DIMM.
(Note: Event Log may contain a recent 00580A4 event denoting detected change in DIMM
population that could be related to this problem.)
2. If no problem is observed on the DIMM connectors or the problem persists, replace the DIMM
identified by LightPath and/or event log entry.
3. If problem re-occurs on the same DIMM connector, replace the other DIMMs on the same
memory channel.
4. Check IBM support site for an applicable service bulletin or firmware update that applies to this
memory error.
5. (Trained Service technician only) If problem re-occurs on the same DIMM connector, inspect
connector for damage. If found, replace system board.
6. (Trained Service technician only) Replace affected Processor.
7. (Trained Service technician only) Replace system board.
• S.51006 [S.51006] A memory mismatch has been detected. Please verify that the memory
configuration is valid.
Explanation: One or More Mismatched DIMMs Detected
Severity
Error
User Response
Complete the following steps:
648
System x3300 M4 Installation and Service Guide