Dsa Lsi Hard Drive Test Results - Lenovo x3300 M4 7382 Installation And Service Manual

Hide thumbs Also See for x3300 M4 7382:
Table of Contents

Advertisement

Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. Check interrupt assignments in the PCI Hardware section of the DSA Diagnostic Log. If the
ethernet device is sharing interrupts, if possible modify the interrupt assignments using F1 Setup
to assign a unique interrupt to the device.
4. Rerun the test.
5. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Lenovo Support website
Latest level of DSA
Latest level of BMC/IMM
• 406-904-000 : IANet:Loopback Test Failed
A failure was detected during the Loopback test.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check the Ethernet cable for damage and ensure correct cable type and attachment.
2. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
3. Rerun the test.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Lenovo Support website
Latest level of DSA
Latest level of BMC/IMM

DSA LSI hard drive test results

The following messages can result when you run the LSI hard drive test.
690
System x3300 M4 Installation and Service Guide