Lenovo x3300 M4 7382 Installation And Service Manual page 441

Hide thumbs Also See for x3300 M4 7382:
Table of Contents

Advertisement

SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive b. Cable from the system board to the
backplane.
3. Replace the following components one at a time, in the order shown, restarting the server each
time: a. Hard disk drive. b. Cable from the system board to the backplane. c. Hard disk drive
backplane. (n = hard disk drive number)
• 806f020d-040fffff : Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 15)
This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d040fffff or 0x806f020d040fffff
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive b. Cable from the system board to the
backplane.
3. Replace the following components one at a time, in the order shown, restarting the server each
time: a. Hard disk drive. b. Cable from the system board to the backplane. c. Hard disk drive
backplane. (n = hard disk drive number)
• 806f0223-2101ffff : Powering off system [ComputerSystemElementName] initiated by
[WatchdogElementName]. (IPMI Watchdog)
This message is for the use case when an implementation has detected a Poweroff by Watchdog has
occurred.
May also be shown as 806f02232101ffff or 0x806f02232101ffff
Severity
Info
Serviceable
No
Automatically notify support
Appendix A. Integrated management module II (IMM2) error messages