Lenovo x3300 M4 7382 Installation And Service Manual page 784

Hide thumbs Also See for x3300 M4 7382:
Table of Contents

Advertisement

No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Lenovo Support website
Latest level of DSA
Latest level of BMC/IMM
• 215-801-000 : Optical Drive Test Aborted
Optical Drive Test Aborted. Unable to communicate with driver.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Make sure that the DSA Diagnostic code is at the latest level.
2. Run the test again.
3. Check the drive cabling for loose or broken connections at both ends or damage to the cable.
Replace the cable if damage is present.
4. Run the test again.
5. Check system firmware level and upgrade if necessary.The installed firmware level can be found
in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
6. Run the test again.
Related links
Lenovo Support website
Latest level of DSA
Latest level of BMC/IMM
• 215-802-000 : Optical Drive Test Aborted
Optical Drive Test Aborted. A read error was encountered.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
772