1. If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a.
Reseat Adapter and any attached cables. b. Reload Device Driver c. If device is not recognized,
reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2 settings can be configured via
F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed
Selection, or the ASU Utility.
2. Check IBM support site for an applicable device driver, firmware update, revision of service
information for this product or other information that applies to this error. Load new device driver
and any required firmware updates.
3. If problem persists, then remove Adapter Card. If system reboots successfully without the
adapter, replace that card.
4. (Trained Service technician only) Replace the processor.
• S.2018001 [S.2018001] An Uncorrected PCIe Error has Occurred at Bus % Device % Function %.
The Vendor ID for the device is % and the Device ID is %.
Explanation: PCIe Uncorrected Error Detected
Severity
Error
User Response
Complete the following steps:
1. If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a.
Reseat Adapter and any attached cables. b. Reload Device Driver c. If device is not recognized,
reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2 settings can be configured via
F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed
Selection, or the ASU Utility.
2. Check IBM support site for an applicable device driver, firmware update, version of service
information for this product or other information that applies to this error. Load new device driver
and any required firmware updates.
3. If problem persists, then remove Adapter Card. If system reboots successfully without the
adapter, replace that card.
4. Trained Service technician only) Replace the processor.
• S.3020007 [S.3020007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this
error.
2. Reflash UEFI image.
3. (Trained service technician only) Replace the system board.
• S.3028002 [S.3028002] Boot permission timeout detected.
Explanation: Boot Permission Negotiation Timeout
Severity
Error
User Response
Complete the following steps: