1. Reconfigure the watchdog timer to a higher value.
2. Make sure that the IMM Ethernet-over-USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
4. Disable the watchdog.
If there was an operating-system error, check the integrity of the installed operating system.
• 4000001d-00000000 : Watchdog [arg1] Failed to Capture Screen.
This message is for the use case where an operating system error has occurred and the screen capture
failed.
May also be shown as 4000001d00000000 or 0x4000001d00000000
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
System - other
SNMP Trap ID
22
CIM Information
Prefix: IMM ID: 0029
User Response
Complete the following steps until the problem is solved:
1. Reconfigure the watchdog timer to a higher value.
2. Make sure that the IMM Ethernet over USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
4. Disable the watchdog. Check the integrity of the installed operating system.
5. Update the IMM firmware. Important: Some cluster solutions require specific code levels or
coordinated code updates. If the device is part of a cluster solution, verify that the latest level of
code is supported for the cluster solution before you update the code.
• 4000001e-00000000 : Running the backup Management Controller [arg1] main application.
This message is for the use case where a Management Controller has resorted to running the backup
main application.
May also be shown as 4000001e00000000 or 0x4000001e00000000
Severity
Warning
Serviceable
No
Automatically notify support
No
Alert Category
System - other
SNMP Trap ID
302