Commissioning
5.4 Basic commissioning
5.4.2.1
Adapting interfaces
Adapting the USB interface
Procedure
Proceed as follows to set the USB interface:
1. Switch on the converter power supply and connect the converter to the PC via USB.
2. The USB drivers are installed if you are connecting the converter and PC together for the
first time. Windows 7 automatically installs the drivers without you having to take any
action. For older Windows versions, acknowledge the corresponding screen forms with
OK.
3. Start the STARTER commissioning software.
4. If you are using STARTER for the first time, you must check the USB interface setting.
To do this, click in STARTER on
If the interface is appropriately set, then the "Accessible nodes" screen form lists the
converters, which are connected via the USB interface. In this case, go to Point 7.
If incorrectly set, then the "No additional nodes found" message is displayed.
5. Acknowledge this message, and set the "Access point" to "DEVICE (STARTER, Scout)"
and the "PG/PC interface" to "S7USB".
6. Then click on "Update". The connected converters are now displayed in "Accessible
nodes".
7. Close this screen form without selecting the converter(s) that has/have been found.
8. Create your STARTER project (Page 88).
You have set the USB interface.
86
("Accessible nodes").
Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
Inverter with CU230P-2 Control Units