Creating An Exception List For The Know-How Protection - Siemens SINAMICS G120 Original Instructions Manual

Sinamics g120 inverter with cu230p-2 control units
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Deactivate know-how protection, delete password
Preconditions
● You are online with STARTER.
● You have inserted the recommended Siemens card. See also Section: Technical data for
Procedure
Proceed as follows to deactivate know-how protection:
1. Select the inverter in the STARTER project, and
right-click to open the dialog box "Know-how
protection drive unit/deactivate ...".
2. There, select the desired option.
• Temporary status: Know-how protection is
• Final status: If you select "Copy RAM to ROM", the inverter immediately deletes the
3. Enter the password and exit the screen form with OK.
You have deactivated know-how protection.
Changing the password
Select the inverter in the STARTER project and open the dialog box via the shortcut menu
"know-how protection drive unit/change password ... ".
9.5.2.2

Creating an exception list for the know-how protection

Using the exception list, you as a machine manufacturer may make individual adjustable
parameters accessible to end customers although know-how protection is active. You may
define the exception list via parameters p7763 and p7764 in the expert list. Specify the
number of parameters for the selection list in p7763. Assign the individual indexes to the
parameter numbers of the selection list in p7764.
Inverter with CU230P-2 Control Units
Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
CU230P-2 (Page 373).
active again after switching the power supply off
and on.
password. If you do not select "Copy RAM to ROM", the inverter deletes the password
the next time the supply voltage is switched off.
Backing up data and series commissioning
9.5 Write and know-how protection
339