Siemens SINAMICS G120 Original Instructions Manual page 47

Sinamics g120 inverter with cu230p-2 control units
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Table 4- 3
Dimensions and clearances for the PM240
Frame size
FSA
FSB
FSC
FSD without filter
FSD with filter
FSE without filter
FSE with filter
FSF without filter
FSF with filter
FSGX
Additional height with shield connection kit: FSA: +84 mm; FSB: +85 mm; FSC: +89 mm; FSD...FSF: +123 mm
1)
You can mount the Power Modules without any lateral clearance up to an ambient temperature of 40 °C in operation.
2)
For tolerance reasons, we recommend a lateral clearance of approx. 1 mm.
You can mount the Power Modules without any lateral clearance. For tolerance reasons, we recommend a lateral
3)
clearance of approx. 1 mm.
Total depth of the inverter: See below.
4)
Table 4- 4
Mounting hardware for PM240
Frame size
FSA, FSB
FSC
FSD, FSE
FSF, FSGX
Table 4- 5
Dimensions and clearances for PM250
Frame size
FSC
FSD without filter
FSD with filter
FSE without filter
FSE with filter
FSF without filter
FSF with filter
Additional height with shield connection kit: FSC: +89 mm; FSD...FSF: +123 mm
1)
You can mount the Power Modules without any lateral clearance up to an ambient temperature of 40 °C in operation.
2)
For tolerance reasons, we recommend a lateral clearance of approx. 1 mm.
You can mount the Power Modules without any lateral clearance. For tolerance reasons, we recommend a lateral
3)
clearance of approx. 1 mm.
Total depth of the inverter: See below.
4)
Inverter with CU230P-2 Control Units
Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
Dimensions (mm)
Height
Width
1)
173
73
270
153
355
140
419
275
512
275
499
275
635
275
634
350
934
350
1533
326
Material
Tightening torque
M4 screws
2.5 Nm
M5 screws
2.5 Nm
M6 screws
6 Nm
M8 screws
13 Nm
Dimensions (mm)
Height
Width
1)
355
140
419
275
512
275
499
275
635
275
634
350
934
350
Depth
a
4)
145
160
36.5
165
258
133
165
343
120
204
325
235
204
419
235
204
405
235
204
541
235
316
598
300
316
899
300
547
1506
125
Depth
a
4)
165
343
120
204
325
235
204
419
235
204
405
235
204
541
235
316
598
300
316
899
300
4.3 Installing Power Modules
Clearances (mm)
b
c
top
--
100
--
100
6
80
11
300
11
300
11
300
11
300
11
350
11
350
14.5
250
Clearances (mm)
b
c
top
6
80
11
300
11
300
11
300
11
300
11
350
11
350
Installing
bottom
lateral
100
30
2)
100
40
2)
100
50
2)
300
0
3)
300
0
3)
300
0
3)
300
0
3)
350
0
3)
350
0
3)
150
50
bottom
lateral
100
50
2)
300
0
3)
300
0
3)
300
0
3)
300
0
3)
350
0
3)
350
0
3)
47