● Reset Communication:
Command specifier and Node_ID indicate the transition states and addressed nodes:
Overview of NMT commands
NMT master - request → NMT slave - message
Command
Start
Stop
Enter Pre-Operational
Reset Node
Reset Communication
Inverter with CU230P-2 Control Units
Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
Command for switching from "Operational", "Pre-Operational" or "Stopped" to
"Initialization". When the Reset Communication command is issued, the converter resets
all the communication objects (1000 hex - 1FFF hex) to the state that was present after
"Power On".
Figure 7-18
CANopen state diagram
Byte 0 (command specifier, CS)
1 (01hex)
2 (02hex)
128 (80hex)
129 (81hex)
130 (82 hex)
7.7 Communication over CANopen
Byte 1
Node ID of the addressed node
Node ID of the addressed node
Node ID of the addressed node
Node ID of the addressed node
Node ID of the addressed node
Configuring the fieldbus
191