5.0 AT Command Line Interface
Description
Get/Set SNMP service.
Command Syntax (Effect: AT&W)
AT+MASNMP[=<Mode>[,<ROCommunity>,<RWCommunity>,<Port>,<Version>]]
Mode:
ROCommunity: Read Only Community Name 1 to 31 characters
RWCommunity: Read Write Community Name 1 to 31 characters
Port: Listening Port 0 to 65535. Default is 161
Version: SNMP version
Example
Input:
AT+MASNMP=1,public,private,161,2<enter>
Response:
OK
© Microhard Systems Inc.
0 - Disable
1 - Enable
1 - Version 1
2 - Version 2
3 - Version 3 (Use AT+MASNMPV3 to set Authentication and Privacy parameters)
AT+MASNMP