Microhard Systems BulletPlus Operating Manual page 196

Bulletplus series. 4g/lte dual sim ethernet/serial/usb gateway w/wifi
Table of Contents

Advertisement

5.0 AT Command Line Interface
Description
Set TCP Server parameters when IP Protocol Mode
is set to TCP Server.
Example
Input:
AT+MCTS2=20002,300<enter>
Response:
OK
Description
Set TCP Client/Server parameters when IP Protocol
is set to TCP Client/Server mode.
Example
Input:
AT+MCCS2=0.0.0.0,20002,60,20002<enter>
Response:
OK
Description
Set UDP Point-to-Point parameters when IP
Protocol is set to UDP Point-to-Point mode.
Example
Input:
AT+MCUPP2=0.0.0.0,20002,20002<enter>
Response:
OK
© Microhard Systems Inc.
Command Syntax (Effect: AT&W)
AT+MCTS2=<Local Listener
Port>,<Connection timeout_s>
Local Listener Port : 1 to 65535
Connection timeout_s: 0 to 65535
Command Syntax (Effect: AT&W)
AT+MCTCS2=<Remote Server IP>,<Remote
Server Port>,<Outgoning timeout_s>,<Local
Listener Port>
Remote Server IP : valid IP address
Remote Server Port : 1 to 65535
Outgoning timeout_s: 0 to 65535
Local Listener Port: 1 to 65535
Command Syntax (Effect: AT&W)
AT+MCUPP2=<Remote IP>,<Remote
Port>,<Listener Port>
Remote IP
: valid IP address
Remote Port : 1 to 65535
Listener Port: 1 to 65535
AT+MCTS2
AT+MCTCS2
AT+MCUPP2