4.0 Configuration
© Microhard Systems Inc.
Name
Description
I/O 1 - 2
Input low state voltage
(Input)
range
Input high state voltage
range
Input leakage current
(3.3 VDC IN)
Typical application input source is a dry switch contact to ground.
Pin includes an internal 56KΩ resistor pull up to 3.3 VDC.
I/O 1 - 2
Open drain drive to
(Output)
ground
Maximum open circuit
voltage applied
Typical application is to drive a relay coil to ground.
Parameter
Min.
VIL
-0.5
VIH
1.5
IIN
—-
Idc
—-
Voc
—-
Table 4-9-1: Digital I/O Specifications
Typ.
Max
Units
0
1.2
V
3.3
30
V
58
—-
µA
100
110
mA
3.3
30
V