5.0 AT Command Line Interface
Description
Get/Set NTP Server.
Example
Input:
AT+MSNTP=1,pool.ntp.org<enter>
Response:
OK
Description
Get/Set syslog server
Example
Input:
AT+MSSYSLOG=192.168.168.35,514<enter>
Response:
OK
Input:
AT+MSSYSLOG?
Response:
OK
Description
Get/Set service status and port.
Example
Input:
AT+MSSERVICE=0,0<enter>
Response:
OK
© Microhard Systems Inc.
Syslog Server : 192.168.168.35
Syslog Port : 514
Command Syntax (Effect: AT&W)
AT+MSNTP=<status>[,<NTP server>[.<Port>]]
Status:
0
Local Time
1
NTP
AT+MSSYSLOG
Command Syntax (Effect: AT&W)
AT+MSSYSLOG=<Server>[,<Port>]
Server : Valid IP Address or Name. 0.0.0.0 -
Disable. 1 to 256 characters
Port: 1 to 65535. Default is 514
AT+MSSERVICE
Command Syntax (Effect: AT&W)
AT+MSSERVICE[=<Service>[,<Mode>[,<Port>]]]
Parameters:
<Service>: 0 - FTP
1 - Telnet
2 - SSH
3 - Microhard Sh
<Mode>:
0 - Disable
1 - Enable
<Port>: 1 to 65535. For Telnet (23 by default)
and SSH (22 by default) only
AT+MSNTP