Remove Key - Toshiba e-STUDIO477S Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO477S:
Table of Contents

Advertisement

[B] 2. Remove Key
Select this to reuse the ADI-HDD as well as the equipment.
When this item is selected, all image data in the HDD are deleted.
This operation requires approx. 20 minutes since the partition must be rebuilt.
When "2" is selected and then [START] button is pressed, the menu below appears.
To start, press the [START] button.
HDD Assist Mode
Current HDD type: ADI HDD
Select number (1-2) and press START key
1. Revert factory initial status HDD
=>

2. Remove key

When the operation is finished, the result appears on the menu.
HDD Assist Mode
Current HDD type: ADI HDD
Select number (1-2) and press START key
1. Revert factory initial status HDD
=>
2. Remove key
Data in the HDD has been erased.
Press SoftPower Key to Switch Off
Notes:
After this operation, the equipment becomes reusable without reinstalling the firmware.
e-STUDIO477S/527S/477SL
SELF-DIAGNOSTIC MODE
System Firmware Version
Update Mode
Confirmation Screen
Are you sure ???
Press START to continue
Press STOP to cancel
Fig. 3-12
System Firmware Version
Update Mode
Fig. 3-13
© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved
3 - 22
: xxxx(x.x.x.x)
: 4c Mode
: xxxx(x.x.x.x)
: 4c Mode