Nad: 40; Others: 2 - Toshiba e-STUDIO477S Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO477S:
Table of Contents

Advertisement

e-STUDIO477S/527S
05/08
Mode
Element
Sub Element
08
Setting
System
General
mode
08
Setting
System
Initialization
mode
08
Setting
System
General
mode
08
Setting
System
User interface
mode
08
Setting
System
General
mode
08
Setting
System
User interface
mode
08 Setting Mode
Sub-
Item
Subitem
Code
Code
9081
9083
9100
9102
9103
9110
Default
Acceptable
Details
value
value
Initialization of department
management information
Initialization of NIC
information
Date and time setting
13 digits
Date display format
Refer to
0~2
contents
Time differences
Refer to
0~47
contents
Auto-clear timer setting
3
0~10
54
RAM
Contents
SYS
Initializing of the department management
information
Enter the code with the digital keys and press the
[INITIALIZE] button to perform the initialization.
If the area storing the department management
information is destroyed for some reason, "Enter
Department Code" is displayed on the control
panel even if the department management function
is not set on. In this case, initialize the area with
this code. This area is normally initialized at the
factory.
SYS
Returns the value to the factory shipping default
value.
-
Year/month/date/day/hour/minute/second
Example:
03 07 01 3 13 27 48
"Day" - "0" is for "Sunday". Proceeds Monday
through Saturday from "1" to "6".
SYS
0: YYYY.MM.DD
1: DD.MM.YYYY
2: MM.DD.YYYY
<Default value>
MJD: 1
JPD: 0

Others: 2

SYS
0: +12.0h 1: +11.5h 2: +11.0h 3: +10.5h 4:
+10.0h 5: +9.5h 6: +9.0h 7: +8.5h 8: +8.0h 9:
+7.5h 10: +7.0h 11: +6.5h 12: +6.0h 13: +5.5h
14: +5.0h 15: +4.5h 16: +4.0h 17: +3.5h 18:
+3.0h 19: +2.5h 20: +2.0h 21: +1.5h 22: +1.0h
23: +0.5h 24: 0.0h 25:-0.5h 26: -1.0h 27: -1.5h
28: -2.0h 29: -2.5h 30: -3.0h 31: -3.5h 32: -4.0h
33: -4.5h 34: -5.0h 35: -5.5h 36: -6.0h 37: -6.5h
38: -7.0h 39: -7.5h 40: -8.0h 41: -8.5h 42: -9.0h
43: -9.5h 44: -10.0h 45: -10.5h 46: -11.0h 47: -
11.5h
<Default value>
MJD: 24

NAD: 40

JPD: 6
Others: 0
SYS
Timer to return the equipment to the default
settings when the [START] button is not pressed
after the function and the mode are set
0: Not cleared
1 to 10:
Set number x 15 sec.
Proc
ServiceUI
edure
3
3
Yes
5
1
1
1
Ver03