Toshiba e-STUDIO477S Service Manual page 389

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO477S:
Table of Contents

Advertisement

e-STUDIO477S/527S
05/08
Mode
Element
Sub Element
08
Setting
System
User interface
mode
08
Setting
System
User interface
mode
08
Setting
System
Scanning
mode
08
Setting
System
General
mode
08
Setting
System
User interface
mode
08
Setting
System
User interface
mode
08
Setting
System
User interface
mode
08
Setting
System
General
mode
08 Setting Mode
Item
Subitem
Code
8704
8709
8710
Hardcopy
8711
security printing
8712
8713
Service
8715
notification
information
8717
Sub-
Default
Details
Code
value
Email/FAX address
0
restriction
Display setting of Service
Refer to
Notification
contents
Designation of language
0
code for ScanToFTP
Enable/Disable setting of
1
watermark information
tracking application
Display setting of the
1
drawer setting button
Setting of web upload/web
1
printing
Password for zip file with
#1048109
password
Shutdown when Super
0
Sleep is enabled
36
Acceptable
RAM
Contents
value
0~1
SYS
0: No restriction
1: Search for external LDAP only
Use this code to restrict address of email/fax to
specified LDAP server. If the value of this code is
set to "1", the addresses of email/fax are restricted
to the LDAP server specified with TopAccess, and
the direct input of addresses and selecting
addresses from the local address book are not
available. If the value of this code is set to "1", this
setting is given priority over the setting value of 08-
9299, 08-3848, 08-3849.
0~1
SYS
Sets whether the [SERVICE NOTIFICATION]
button is displayed on the screen accessed by
[USER FUNCTIONS] -> [ADMIN] -> [SERVICE].
0: Disabled
1: Enabled
<Default value>
JPD/NAD/MJD: 1
Others: 0
0~2
SYS
0: Automatic selection
1: UTF8
2: Shift-JIS
0~1
SYS
Set this code to "1: Disabled" to disable the
watermark information tracking application at
hardcopy security printing. When this code is set to
"1: Disabled", a license error occurs even if the
license for hardcopy security printing is enabled. If
this error occurs, hardcopy security printing is
available, but copy prohibition function and tracking
application are not available.
0: Disabled
1: Enabled
0~1
SYS
Sets whether the drawer button in USER
FUNCTIONS is displayed or not.
0: Not displayed
1: Displayed
0~1
SYS
Sets whether the web upload and web printing
function is enabled or disabled.
- Web upload is a function which uploads the
image data created on the equipment to the web
page displayed on EWB.
- Web printing is a function which prints the web
page displayed on EWB or the PDF file included in
the web page displayed on EWB.
0: Disabled
1: Enabled
SYS
Password for zip file with password of service
notification information.
Minimum number of digits: 0, maximum number of
digits: 20
Available character: alphanumeric characters and
symbols
0~1
SYS
Sets the operation when the power button is
pressed for a few seconds if Super Sleep is
enabled.
0: Hibernation 1: Super Sleep
Proc
ServiceUI
edure
1
1
Yes
1
1
1
Yes
1
11
1
Yes
Ver03

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio527sE-studio477sl

Table of Contents