E-Mail Related Error; Message Reception Error; Exceeding File Capacity; Directory Creation Failure - Toshiba e-STUDIO477S Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO477S:
Table of Contents

Advertisement

[ 5 ]

E-mail related error

[2C10] System access abnormality
[2C32] File deletion failure
Turn the power OFF and then back ON. Perform the job in error again.
If the error still occurs, first, check if there are no jobs existing and then perform the HDD formatting
([5] + [C] + [POWER] ON -> [3] -> [1]).
[2C11] Insufficient memory
When there are running jobs, perform the job in error again after the completion of the running jobs.
If the error still occurs, turn the power OFF and then back ON, and perform the job again.
[2C12] Message reception error
[2C13] Message transmission error
Turn the power OFF and then back ON. Perform the job in error again.
[2C14] Invalid parameter
When a template is used, form the template again.
If the error still occurs, turn the power OFF and then back ON, and perform the job again.
[2C15] Exceeding file capacity
Reset and extend the "Maximum send to E-mail/iFAX size" or reduce the number of pages and
perform the job again.
[2C20] System management module access abnormality
[2C21] Job control module access abnormality
[2C22] Job control module access abnormality
Turn the power OFF and then back ON. Perform the job in error again.
Check if there are no other running jobs and perform the HDD formatting ([5] + [C] + [POWER] ON
-> [3] -> [1]).
If the recovery is still not completed, replace the SYS board.
[2C30] Directory creation failure
[2C31] File creation failure
[2C33] File access failure
Check if the access privilege to the storage directory is writable.
Check if the server or local disk has a sufficient space in disk capacity.
[2C40] Image conversion abnormality
[2C62] Memory acquiring failure
Turn the power OFF and then back ON. Perform the job in error again.
Replace the main memory and perform the job again.
[2C43] Encryption error
Turn the power OFF and then back ON. Perform the job in error again.
[2C44] Encryption PDF enforced mode error
Reset the encryption and perform the job in error again.
If an image file not encrypted is created, consult your administrators.
[2C45] Meta data creation error (Scan to Email)
Check the template settings. Perform the job in error again. If the error still occurs, turn the power
OFF and then back ON, and then perform the job in error again.
[2C60] HDD full failure during processing
Delete the job in progress or being set or in the HOLD/PRIVATE/PROOF/INVALID, and perform it
again.
Check if the server or local disk has a sufficient space in disk capacity.
Check that there is enough space in the server or local disk.
e-STUDIO477S/527S/477SL
ERROR CODE AND TROUBLESHOOTING
© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved