Toshiba e-STUDIO477S Service Manual page 427

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO477S:
Table of Contents

Advertisement

e-STUDIO477S/527S
05/08
Mode
Element
Sub Element
08
Setting
System
Maintenance
mode
08
Setting
System
Maintenance
mode
08
Setting
System
Maintenance
mode
08
Setting
System
Network
mode
08
Setting
System
Network
mode
08
Setting
System
Wireless LAN
mode
08
Setting
System
Network
mode
08
Setting
System
Maintenance
mode
08
Setting
System
User interface
mode
08
Setting
System
Maintenance
mode
08
Setting
System
Network
mode
08
Setting
System
Maintenance
mode
08
Setting
System
Maintenance
mode
08
Setting
System
Maintenance
mode
08
Setting
System
Maintenance
mode
08
Setting
System
Maintenance
mode
08
Setting
System
Maintenance
mode
08 Setting Mode
Item
Subitem
Code
RDMS
Remote-controlled
9620
service polling day
Remote-
Information of
9624
controlled service
supplies
RDMS
Long interval
9626
polling
InternetFax
9627
SMTP
9628
9649
DHCP
9694
General
9700
9702
General
9703
Scanning
9709
RDMS
General
9710
RDMS
HTTP
9711
RDMS
HTTP
9715
RDMS
9718
RDMS
9719
RDMS
General
9723
Sub-
Default
Details
Code
value
Saturday
1
Setting of toner cartridge K
0
Setting of polling at the end
0
of month
Sending mail text of Internet
1
FAX
From Name Creation
0
setting in SMTP
authentication
Wireless LAN setting
2
Enabling server's IP
1
address acquired by DHCP
Service technician
0
telephone number
Automatic calibration
1
disclosure level
Error history display
Default data saving
0
directory of "Scan to File"
Remote-controlled service
2
function
Remote-controlled service
URL setting
Initially-registered server
Refer to
URL setting
contents
Short time interval setting of
24
recovery from Emergency
Mode
Short time interval setting of
60
Emergency Mode
Periodical polling timing
1530
74
Acceptable
RAM
Contents
value
0~1
SYS
0: Invalid
1: Valid
0~1
SYS
0: Invalid
1: Valid
0~1
SYS
0: Invalid
1: Valid
0~1
SYS
0: Invalid
1: Valid
0~2
SYS
0: Not edited
1: Account name of From Address +Device name
2: LDAP searching
1~2
NIC
Sets whether the wireless LAN connection is
enabled or disabled.
1: Enabled
2: Disabled
1~2
-
DNS domain name Option (15) DNS domain name
of the client
1: Enabled
2: Disabled
This value is used only when DHCP is enabled.
32 digits
SYS
A telephone number can be entered up to 32
digits.
Use the [MONITOR/PAUSE] button to enter a
hyphen(-).
0~2
SYS
Sets the disclosing level of automatic calibration.
0: Service technician
1: Administrator
2: User
SYS
Displays the latest 20 errors data
0~2
SYS
0: Local directory
1: REMOTE 1
2: REMOTE 2
0~2
SYS
0: Valid (Remote-controlled server)
1: Valid (L2)
2: Invalid
SYS
Maximum 256 letters
SYS
Maximum 256 letters
<Default value>
https://device.mfp-
support.com:443/device/firstregist.ashx
1~48
SYS
Sets the time interval to recover from the
Emergency Mode to the Normal Mode.
(Unit: Hour)
30~360
SYS
Unit: Minute
0~2359
SYS
(Hour/Hour/Minute/Minute)
0 (0:00) to 2359 (23:59)
Proc
ServiceUI
edure
1
1
1
Yes
1
1
12
12
11
Yes
1
2
Yes
1
1
Yes
11
Yes
11
Yes
1
Yes
1
Yes
1
Yes
Ver03

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio527sE-studio477sl

Table of Contents