4.4

Image Quality Adjustment (Scanning Function)

4.4.1
Gamma balance adjustment
The gamma balance at the Black Mode is adjusted by adjusting the density. The adjustment is
performed by selecting its density area from the following: low density, medium density and high
density.
<Adjustment Mode (05)>
Black
Original mode
Text/
Text
Photo
Photo
7485 -0
7487 -0
-
7485 -1
-
7487 -1
7485 -2
-
7487 -2
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Key in the code corresponding to the desired original mode and press the [START] button.
(3)
Key in the value corresponding to the density area to be adjusted (0, 1 or 2) and press the
[START] button.
0: Low density (L), 1: Medium density (M), 2: High density (H)
(4)
Key in the adjustment value. (To correct the value once keyed in, press the [CLEAR] button.)
(5)
Press the [OK] or [INTERRUPT] button to store the value in memory.
 The equipment goes back to the ready state.
(6)
For resetting the value, repeat step (2) to (5).
(7)
Let the equipment restart and perform the scanning job.
(8)
If the desired image has not been attained, repeat step (1) to (7).
e-STUDIO477S/527S/477SL
SETTING / ADJUSTMENT
Gray
Item to be
Scale
adjusted
Custom
mode
7488 -0
7480-0
Low density
7480-1
7488 -1
Medium density
7480-2
7488 -2
High density
4 - 14
Remarks
The larger the value is, the density of the
item to be adjusted becomes darker.
Acceptable values: 0 to 255
(Default: 128)