[8127] Domain - Invalid logon hours for the User
Classification
Network error
Check item
Setting
[8128] Active Directory Domain - Clock Skew error due to difference in Time between Server and
MFP
Classification
Network error
Check item
Setting
[8129] Active Directory Domain - Kerberos Ticket has expired and cannot be used for Authentication
Classification
Network error
Check item
Setting
[812A] Active Directory Domain - Verification of the Ticket has failed
Classification
Network error
Check item
Setting
[812B] Active Directory Domain-The Domain specified could not be found
Classification
Network error
Check item
Setting
e-STUDIO477S/527S/477SL
ERROR CODE AND TROUBLESHOOTING
The user log-on time is invalid at domain authentication and
the user cannot log-on.
Check the log-on time setting of the user account in "Active
Directory User and Computer".
The difference between the time set in the equipment and
that set in the server is more than five minutes at domain
authentication of the Active Directory and the user cannot log
on.
Match the time of the equipment and domain controller, or if
an SNTP server is in the network, recommend the use of
SNTP.
A Kerberos ticket has expired at the domain authentication of
the Active Directory and the user cannot log on.
Check if the Kerberos ticket on the Kerberos server has
expired.
A Kerberos ticket authentication error of the Active Directory
domain authentication occurs and the user cannot log on.
Check if the user name or password is correctly entered. If
this problem still persists, contact your Window server
administrator.
The Realm name for the domain authentication of the Active
Directory is invalid and the user cannot log on.
Check if the Realm name of the Active Directory server of the
equipment is wrong. If this problem still persists, contact your
Window server administrator.
© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved
5 - 108
Error item
Measures
Error item
Measures
Error item
Measures
Error item
Measures
Error item
Measures

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio527sE-studio477sl

Table of Contents