Notes:
"Update Failed." is displayed at the bottom of the LCD screen when the update is not
completed properly. "Failed" appears next to the failed item on the status display. Even
though an update fails, do not turn the power OFF until other updates are finished. If "Update
Failed" appears at the bottom of the screen, turn OFF the power and then check the following
items. After confirming and clearing the problems, restart updating from the beginning.
-
Does the USB device meet the conditions to be used for updating?
-
Is the data file written properly in the USB device?
-
Is the USB device installed properly?
-
Do the USB device and equipment operate properly?
The integrity check system is automatically operated before firmware updating. During this
operation, "Verifying Signature..." and "Progress: **%" are displayed on the LCD screen.
When the check is completed properly, no message for notifying the success will appear and
the firmware updating will start. If it fails, "Invalid Signature" and "Copy Data with >valid
signature in USB" will be shown. In that case, firmware updating cannot be performed, so turn
the power OFF and disconnect the USB device. Check that there is no abnormality in the
firmware data, and reperform the update.
When a system firmware (OS Data) update error or system software (HD Data) update error
occurs, "Update Failed" or "Failed" appears on the screen and the error number appears next
to the message.
For details of each error, refer to the following tables.
Error number
O01
FROM writing failed
O02
FROM verification error
O03
File operation error
O04
SRAM flag set error
O05
Electronic key data backup error
O06
Device error
Error number
H01
File creation error
H02
File decompression error (Out of free disk space on the HDD at file extraction)
H03
Partition mount error
H00
Other errors
© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved