[71AA] Unidentified error during certificate acquisition from SCEP server
Classification
Maintenance error
Check item
Setting
[71AB] Timeout error during certificate acquisition from SCEP server
Classification
Maintenance error
Check item
Setting
[71AC] File save error during certificate acquisition from SCEP server
Classification
Maintenance error
Check item
Setting
[71B0] Software package file decryption failure
Classification
Maintenance error
Check item
Setting
e-STUDIO477S/527S/477SL
ERROR CODE AND TROUBLESHOOTING
Unidentified error occurred during certificate acquisition from
SCEP server.
Check SCEP server and the SCEP setting (automatic) on the
TopAccess screen as follows: TopAccess Administration
Security Certificate Management
Timeout error occurred during certificate acquisition from
SCEP server.
Check SCEP server and the SCEP setting (automatic) on the
TopAccess screen in the following procedure: TopAccess
Administration Security Certificate Management
File save error occurred during certificate acquisition from
SCEP server.
File saving failed for some reason. If the error still occurs after
rebooting the equipment, start up using the following
procedure:[3] + [C] + [POWER] 3. HDD formatting
Reinstallation of software or HDD replacement
Software package file decryption failed.
Software package file may have a problem or may be
corrupted. Check the software package file and then
reattempt the installation.
© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved