10.3 Notices

10.3.1

Setting code

Each signal will be enabled by configuring the setting code "08-9016" (Counter installed externally).
08-9016
0: No external counter (Default)
1: Coin controller
5: Coin controller supporting mixed-size
10.3.2
Setting value change and restrictions when using the coin
controller
08-9016 (Counter installed externally): Set to "1" (Coin controller) or "5" (Coin controller supporting
mixed-size).
Notes:
When "5" is set for 08-9016, the coin controller supports "mixed-size" and will perform the size
signal switching process for every page.
The setting items regarding the fee charging system below must be set correctly according to
the usage.
-
08-9017 (Setting for counter installed externally): To charge only when copies are made,
set to "1".
-
08-6011 (Large size double count setting): Set to "0" when A3 and LD are specified as the
large size, and set to "1" when B4, LG, FOLIO, COMP and 8K are specified as the large size
in addition to A3 and LD.
10.3.3

Restrictions when using the external counter

The Job Skip function will be disabled when an external counter is installed (when a value other than
"0" is set for 08-9016).
Therefore, if printing is attempted while a counter or a coin controller is used, all jobs stored in the HDD
may be printed.
© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved