[F200] Data Overwrite option (GP-1070) disabled
Classification
Other service call
Check item
Setting

[F500] HD partition damage

Classification
Other service call
Check item
Setting
Replace parts

[F510] Application start error

Classification
Other service call
Check item
Setting
© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved

Data Overwrite option (GP-1070) disabled

Perform firmware installation (all firmware: OS, HDD, SYS,
Engine Main Firmware, and Scanner Firmware) with the USB
device.
* When the function of the Data Overwrite option (GP-1070) is
deleted from the equipment, the service call "F200" occurs.
Perform 08-3840 to install the Data Overwrite Enabler (GP-
1070).
* If F200 occurs while High (Åg3Åh) is set for the security level
(08-8911), it cannot be released by installing the firmware
using the USB device. Install the Data Overwrite Enabler
(GP-1070) by 08-384.
The file system is abnormal.
Diagnose the file system with [5] + [C] + [POWER]  1.
Check F/S, and then recover the problem partition with [5]
+ [C] + [POWER]  2. Recovery F/S.
If it is not recovered, reinstall the software after the HDD
format.
The application fails to start.
1. Reboot.
2. If it has still not recovered, reinstall the system software.
3. If it still persists after step 2, perform [3] + [C] + [POWER]
 3, and then reinstall the system software.
Notes:
User data will be deleted when [3] + [C] + [POWER] 
3 is performed.