e-STUDIO477S/527S
05/08
Mode
Element
Sub Element
08
Setting
System
User interface
mode
08
Setting
System
User interface
mode
08
Setting
System
User interface
mode
08 Setting Mode
Item
Subitem
Code
Card reading
3500
device
Card reading
3501
device
Card reading
3502
device
Sub-
Default
Details
Code
value
Device setting
0
Card reader format
0
information -1
Card reader format
0
information -2
1
Acceptable
RAM
Contents
value
0~4294967
SYS
To enable the e-Bridge ID Gate, a card reading
295
device should be set in the order of "ABYYZZZZ".
(Enter the corresponding values to "A", "B", "YY"
and "ZZZZ".)
- AB: Special setting
- A: Debugging NIC
0: Not used 1: Used
- B: Interface
0: USB connection 1: Serial connection (KP-2003
only)
- YY: Authentication
00: No authentication using card
02: FeliCa (KP-2003 only)
03: Mifare (KP-2005 only)
04: HID (KP-2004 only)
07: USB keyboard emulation authentication device
08: Q-tag
09: Magnetic card I/F
10: NFC (Common setting for Felica/Mifare)
11: NFC (Separate setting for Felica/Mifare)
12: NFC (Dedicated setting for Felica)
13: NFC (Dedicated setting for Mifare)
- ZZZZ: Sub-code (Specifies the usage type of card
ID)
0000: No authentication using card
0001: IDm (Felica/NFC-Felica) and (or) UID
(Mifare/NFC-Mifare)
0002: Data (Felica/NFC-Felica/Mifare/NFC-Mifare)
0003: SSFC mode
0~4294967
SYS
To access the data in the noncontact IC card, the
295
Key Information "LLLL" and the Sector Number
"MMMM" should be set.
The "LLLL" should be set first, and then "MMMM".
KP-2003:
LLLL: System code (hexadecimal number)
MMMM: Service code (hexadecimal number)
KP-2005:
LLLL: Key information
MMMM: Sector number (hexadecimal number)
0~4294967
SYS
The data of the block number in the noncontact IC
295
is set.
KP-2003: <PPQRSSTU (hexadecimal number)>
PP: 1st block
Q: 1st block beginning byte
R: 1st block ending byte
SS: 2nd block
T: 2nd block beginning byte
U: 2nd block ending byte
KP-2005: <RRBSEbse (hexadecimal number)>
RR: 00 (Fixed)
B: 1st area block number
S: 1st area beginning byte offset
E: 1st area ending byte offset
b: 2nd area block number
s: 2nd area beginning byte offset
e: 2nd area ending byte offset
* If the 2nd block/area is not used, set the SSTU to
"FFFF" (hexadecimal number), the bse to"FFF"
(hexadecimal number).
Proc
ServiceUI
edure
5
5
Yes
5
Yes
Ver03