Dc Link/Motor Connection - Siemens SINAMICS S120 Equipment Manual

Chassis power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor Modules
4.3 Interface description
4.3.3

DC link/motor connection

Table 4- 2
DC link/motor connection of the Motor Module
Terminals
DCP, DCN
DC power input
DCPA, DCNA
Connection for Braking
Module
DCPS, DCNS
connection for a dv/dt
filter plus VPL
U2, V2, W2
3 AC power output
PE connection
PE1, PE2
152
Technical specifications
Voltage:
510 V to 720 V DC
675 V to 1035 V DC
Connections:
Frame sizes FX / GX: Thread M10 / 25 Nm for ring cable lugs to DIN 46234
Frame sizes HX / JX: d = 13 mm (M12/50 Nm) flat connector for busbar
Voltage:
510 V to 720 V DC
675 V to 1035 V DC
Connections:
Frame sizes FX / GX: Threaded bolt M6 / 6 Nm for ring cable lugs to DIN 46234
Frame sizes HX / JX: d = 13 mm (M12/50 Nm) flat connector for busbar
Voltage:
510 V to 720 V DC
675 V to 1035 V DC
Connections:
Frame sizes FX / GX: Threaded bolt M6 / 6 Nm for ring cable lugs to DIN 46234
Frame sizes HX / JX: d = 11 mm (M10 / 25 Nm) for ring cable lugs to DIN 46234
Voltage:
0 VAC, 3-phase, to 0.72 x DC link voltage
Connecting thread:
Frame sizes FX / GX: M10 / 25 Nm for ring cable lugs to DIN 46234
Frame sizes HX / JX: M12 / 50 Nm for ring cable lugs to DIN 46234
Connecting thread:
Frame sizes FX / GX: M10 / 25 Nm for ring cable lugs to DIN 46234
Frame sizes HX / JX: M12 / 50 Nm for ring cable lugs to DIN 46234