Table 149 Show Monitor Command Information; Show Mstp Command - ZyXEL Communications MSC1000G User Manual

Ies-5000 series management switch card
Hide thumbs Also See for MSC1000G:
Table of Contents

Advertisement

The following example displays the hardware monitor statistics for the line card in slot 7.
ras> show monitor 7
'*' indicates a current alarm
voltage:
idx
volt
---
---------------- -------- -------- -------- --------
1
1.2V
2 * 1.8V
3
3.3V
4
20.5V
temperature:
idx
temperature
---
---------------- -------- -------- --------
1
Temp1
2
Temp2
3
Temp3
ras>
This table describes labels in the example.

Table 149 show monitor Command Information

LABEL
voltage
current
nominal
high_lmt
low_lmt
temperature
current
high_lmt
low_lmt

27.3.16 show mstp Command

Syntax:
show mstp <mstid> [<end_mstid>]
where
<mstid>
<end_mstid>
Chapter 27 show Commands
current
nominal
1.187
1.200
1.976
1.800
3.263
3.300
20.596
20.500
current
high_lmt low_lmt
58.000
95.000
54.000
90.000
51.000
85.000
DESCRIPTION
The power supply for each voltage has a sensor that can detect and report the
voltage.
This is the present voltage reading.
This field displays the average voltage measured at this sensor.
This field displays the high voltage threshold for this sensor.
This field displays the low voltage threshold for this sensor.
This example displays the temperature measurements in degrees Celsius.
Each temperature sensor can detect and report the temperature. Temperature
sensor 1 is near the ADSL line driver. Temperature sensor 2 is near the ADSL
chipset. Temperature sensor 3 is near the central processing unit.
This shows the current temperature at this sensor.
This field displays the high temperature threshold for this sensor.
This field displays the low temperature threshold for this sensor.
=
The first MST region ID.
=
The last MST region ID.
MSC1000G User's Guide
high_lmt low_lmt
1.284
1.116
1.926
1.674
3.531
3.069
22.550
18.450
-50.000
-50.000
-50.000
445

Advertisement

Table of Contents
loading

Table of Contents