Interface Modules - Brocade Communications Systems NetIron MLXe Series Hardware Installation Manual

Table of Contents

Advertisement

Router modules
TABLE 7 Management module LEDs
LED
Port 1 and Port 2
Active
Pwr
10/100/1000 Ethernet Port
10/100/1000 Ethernet Port
Pre-installation notice for Brocade MLXe Series chassis bundles with MR2 management modules
The following conditions must be met for any chassis with a MR2 management module to operate properly.
The MR2 module requires a minimum software version of R05.2.00b to operate. Do not attempt to downgrade the MR2
module to a release lower than R05.2.00b.
MR2-M and MR2-X modules cannot be mixed together in any MLXe chassis
MR and MR2 modules cannot be mixed together in any MLXe chassis
Do not downgrade the MBRIDGE version on the MR2 module.
The MR2 management module requires MBRIDGE version 36 or later for 4-, 8-, and 16-slot devices
The MR2 management module requires MBRIDGE32 version 35 or later for 32-slot devices
In certain module combinations, you will need to make sure the supported software is loaded.

Interface modules

Three generations of interface modules exist for Brocade MLXe Series routers.
The following table lists interface modules that are available for Brocade MLXe Series routers.
TABLE 8 Interface modules for all Brocade MLXe Series routers
SKU
BR-MLX-100GX2-CFP2-M
32
Position
Each adjacent to the auxiliary flash
slot that it represents
Lower Left
Upper Left
Above and right of RJ-45
connector
Above and left of RJ-45 connector
Ports
2
State
On or blinking
Off
On
Off
On
Off
On (Green)
Off
On or blinking (Yellow)
Off for an extended period
Description
Brocade MLXe two (2)-port 100-
GbE (M) module with IPv4/IPv6/
MPLS hardware support. Requires
CFP2 optics. Supports 512K IPv4
routes in FIB. Requires high speed
switch fabric modules.
Brocade NetIron MLXe Series Hardware Installation Guide
Meaning
The software is currently accessing
the auxiliary flash card.
The software is not currently
accessing an auxiliary flash card,
although there is one inserted in the
slot.
The module is functioning as the
active management module.
The module is functioning as the
redundant management module.
The module is receiving power.
The module is not receiving power.
A link is established with the remote
port.
No link is established with the
remote port.
The port is transmitting and
receiving packets.
The port is not transmitting or
receiving packets.
Generation
Gen 3
53-1004203-04

Advertisement

Table of Contents
loading

Table of Contents