Hardware specifications for Brocade MLXe Series
routers
The following sections describe hardware specifications for Brocade MLXe Series routers.

Power specifications

The following power supply frequency requirements apply to Brocade MLXe Series-4, Brocade MLXe Series-8, and Brocade MLXe
Series-16 routers:
AC Input Rating: 100 to 240V, 50/60 Hz, 16.0 A maximum per power supply
1200W Power Output for 1200W PSU (100-240V)
1200W Power Output for 1800W PSU (100-180V)
1800W Power Output for 1800W PSU (180-240V)
AC Operating Voltage Range: 90 to 264V, 50/60 Hz
Inrush current <60A peak for any initial current surge or spike of 10mS or less at either cold or warm start. Any additional
inrush current surges or spikes in the form of AC cycles or multiple AC cycles greater than 10mS and less than 150mS will
be <25A peak.
DC Input Rating: -48V
40A maximum per power supply (1200W PSU)
60A maximum per power supply (1800W PSU)
DC Operating Range: -40 to -60V
Inrush current <80A peak for any initial current surge or spike of 10mS or less at either cold or warm start.
The following power supply frequency requirements apply to the Brocade MLXe Series 32-slot routers:
AC Input Rating: 200 to 240V, 50/60 Hz, 16.0 A maximum per power supply
AC Operating Voltage Range: 180 to 264V
Inrush current <60A peak for any initial current surge or spike of 10mS or less at either cold or warm start. Any additional
inrush current surges or spikes in the form of AC cycles or multiple AC cycles greater than 10mS and less than 150mS will
be <25A peak.
DC Input Rating: -48V
75A maximum per power supply (2400W PSU)
80A maximum per power supply (3000W PSU)
DC Operating Range: -40 to -60V
Inrush current <70A peak for any initial current surge or spike of 10mS or less at either cold or warm start.