Brocade Communications Systems NetIron MLXe Series Hardware Installation Manual page 205

Table of Contents

Advertisement

SNM3: not present
LP1 Sensor1: 41.5C
LP1 Sensor2: 50.625C
LP4 Sensor1: 39.0C
LP4 Sensor2: 49.250C
LP4 Sensor3: UNUSED
LP4 Sensor4: 38.5C
LP4 Sensor5: 47.750C
LP4 Sensor6: UNUSED
Fans are in auto mode. Temperature Monitoring Poll Period is 60 seconds
The following table describes the show chassis command output.
TABLE 38 show chassis command output
Field
Powers
Power num , part num
Power status
Total power budget for device
Total power used by system core
Total power used by LPs
Total power available
Slot Power-On Priority
Slot num
Slot1 - Slot16
4-slot device: Slot1 - Slot48-slot device: Slot1 - Slot816-slot device:
Slot1 - Slot1632-slot device: Slot1 - Slot32
Brocade NetIron MLXe Series Hardware Installation Guide
53-1004203-04
Description
The Powernum is the power supply number as positioned in the device.
The number of power supplies are as follows:
4-slot devices: 1 - 38-slot devices: 1 - 416-slot devices: 1 - 832-slot
devices: 1 - 8
The part num is the part number of the power supply purchased. This
applies to AC and DC power supplies.
Indicates whether an AC or DC power supply is installed in the specified
power supply slot and the status of the power supply, which can be one of
the following:
Installed (Shutdown) - The power supply has shut down. A
power supply will shut down due to flapping, or if a shut down is
enabled manually using the power-off power-supply command.
Refer to
Enabling a power supply shutdown
Installed (OK) - The power supply is functioning properly and
supplying power to the device and installed modules.
Failed - The power supply is not functioning and is not
supplying power to the device and installed modules.
not present - There is no power supply installed in the slot.
Installed (Failed or Disconnected) - The power supply is not
functioning, or the power supply is not connected to the device
and installed modules.
The sum of all power (in watts), used by all power supplies currently
functioning in the device. Refer to
MLXe Series routers
on page 271.
The total power used by the management modules, switch fabric
modules, and fans. Each component consumes different amounts of
power.
The total power used by the interface modules. Each module type
consumes different amounts of power.
The total power budget for the device minus the total power used by the
system core and the installed interface modules.
The configured power-on priority of each interface module.
The slotnum is the device slot number.
The priority of each device slot as configured by the lp-slot-priority
command. The priority can be 1 (low, default) - 8 (high). If the amount of
power supplied to the device falls below a minimum threshold, the device
slots with the lowest priority will likely lose power. For information about
using the lp-slot-priority command, refer to
interface modules
on page 224.
Managing the device
on page 252.
Hardware specifications for Brocade
Changing priority of slots for
205

Advertisement

Table of Contents
loading

Table of Contents