Displaying Fabric Link Status; Syslog Messages - Brocade Communications Systems NetIron MLXe Series Hardware Installation Manual

Table of Contents

Advertisement

Monitoring Link Status

Displaying fabric link status

To display the fabric link status, enter the following command:
MLX#show sfm-links 1
SFM#/FE# | FE link#
----------+-----------+---------+-----------+---------
1 / 1
|
13
1 / 1
|
17
1 / 1
|
14
Syntax: show sfm-links sfm-number | all [ errors ]
The sfm-number variable specifies an SFM that you want to display link information for.
The all option displays link information for all SFMs in the chassis.
The errors option only displays information for SFM links that are in the DOWN state.
The output of this command can also be filtered using an output modifier. To use an output modifier, type a vertical bar ( | ) followed by a
space and one of the following parameters:
begin - begin output with the first matching line
exclude - exclude matching lines from the output
include - include only matching lines in the output
A warning statement is sent if the number of operational links falls below the minimum threshold.
This warning is displayed to warn users that the line rate traffic will not be maintained.
The following table describes the information the show sfm-links command displays.
TABLE 46 CLI display of SFM link information
This field...
SFM#
FE#
FE link#
LP#
TM#
TM link#
link state

Syslog messages

The following syslog messages are related to link monitoring:
System: Interface Ethernet 3/1, state down -fabric connectivity down
System: Interface Ethernet 3/1, state up -fabric connectivity up
226
| LP#/TM# | TM link#
| 2 / 1
|
13
|
| 2 / 2
|
01
|
| 2 / 1
|
01
|
| link state
UP
DOWN
UP
Displays...
The switch fabric module number.
The FE number.
The number of the interconnect between the SFM and the FE.
The slot number where the Interface module (LP) is installed.
The number of the traffic manager used in the link.
The link number on the traffic manager.
The link state is either:
UP - In an operating condition
DOWN - In a non-operational condition
Brocade NetIron MLXe Series Hardware Installation Guide