Brocade Communications Systems NetIron MLXe Series Hardware Installation Manual page 37

Table of Contents

Advertisement

Performance in Turbo mode:
Line-rate with all SFMs installed except for some small packet sizes
No line-rate without all SFMs installed.
Performance in non Turbo mode:
No line-rate even with all SFMs installed.
NOTE
Dynamic port configuration for the 2x100GbE CFP2 based high density blade chassis is shown in the topic
Dynamic Port Configuration
FIGURE 7 2x100GbE CFP2 interface module front panel
1.
Pwr LED - if green: All power rails are functional and module is receiving
power. If not lit (off): One or more power rails have failed and module is not
receiving power.
2.
1 Link/Act LED: If green: CFP2 port 1 is functional. If not lit (off): CFP2
port 1 is not active.
2x100GbE CFP2 LED indicators and chassis support tables
LED indicators for the 2x100GbE CFP2 based high density blade indicate the status of each port, as described in the following table.
TABLE 9 2x100GbE CFP2 LED Indicators
LED Function/state
Power module state (LED)
Controlled by the downloader FPGA; this
LED is hardware controlled and is not
software accessible.
Link/Act
Chassis support for the 2x100GbE CFP2 based high density blade is shown in the following table.
TABLE 10 2x100GbE CFP2 Chassis Support
Ports
2x100GbE CFP2
Brocade NetIron MLXe Series Hardware Installation Guide
53-1004203-04
on page 275.
Location
Left side of module
Adjacent to each port.
Chassis Supported
MLXe
3.
2 Link/Act LED: If green: CFP2 port 2 is functional. If not lit (off): CFP2
port 2 is not active.
Meaning
GREEN: All power rails are
functional and module is
receiving power.
OFF: One or more power rails
have failed and module is not
receiving power.
GREEN: All ports are functional.
OFF: One or more ports have
failed.
Description
Support in MLXe.
Router modules
2x100GbE CFP2
Possible cause
Power rails are enabled.
Power rails are disabled.
Port is enabled and link is up.
Port is disabled.
37