Brocade Communications Systems NetIron MLXe Series Hardware Installation Manual page 181

Table of Contents

Advertisement

8.
Enter the write memory command to save the new configuration.
The following example demonstrates the forced card deletion feature:
device#show module
Module
M1 (left):BR-MLX-MR2-M Management Module
M2 (right):NI-MLX-MR Management Module
F1:
F2: NI-X-HSF Switch Fabric Module
F3: NI-X-HSF Switch Fabric Module
S1: BR-MLX-40Gx4-M 4-port 40GbE Module
S2: NI-MLX-10Gx8-D 8-port 10GbE (D) Module
S3: NI-MLX-10Gx8-D 8-port 10GbE (D) Module
S4: NI-MLX-10Gx8-M 8-port 10GbE (M) Module
S5: NI-MLX-10Gx8-M 8-port 10GbE (M) Module
S6: NI-MLX-1Gx20-GC 20-port 10/100/1000
Copper Module
S7: NI-MLX-10Gx8-M 8-port 10GbE (M) Module
S8: BR-MLX-40Gx4-M 4-port 40GbE Module
device#
device#show running-config | include module
module 1 br-mlx-4-port-40g-m
module 2 ni-mlx-8-port-10g-d
module 3 ni-mlx-8-port-10g-d
module 4 ni-mlx-8-port-10g-m
module 5 ni-mlx-8-port-10g-m
module 6 ni-mlx-20-port-1g-copper
module 7 ni-mlx-8-port-10g-m
module 8 br-mlx-4-port-40g-m
snmp-server max-ifindex-per-module 64
NOTE
At this stage of the process, the module is physically swapped.
device#show module
Module
M1 (left ):BR-MLX-MR2-M Management Module
M2 (right):NI-MLX-MR Management Module
F1:
F2: NI-X-HSF Switch Fabric Module
F3: NI-X-HSF Switch Fabric Module
S1: BR-MLX-40Gx4-M 4-port 40GbE Module
S2: NI-MLX-10Gx8-M 8-port 10GbE (M) Module
(S2: Configured as NI-MLX-10Gx8-D 8-port 10GbE (D) Module)
S3: NI-MLX-10Gx8-D 8-port 10GbE (D) Module
S4: NI-MLX-10Gx8-M 8-port 10GbE (M) Module
S5: NI-MLX-10Gx8-M 8-port 10GbE (M) Module
S6: NI-MLX-1Gx20-GC 20-port 10/100/1000
Copper Module
S7: NI-MLX-10Gx8-M 8-port 10GbE (M) Module
S8: BR-MLX-40Gx4-M 4-port 40GbE Module
device#configure terminal
device(config)#no module 2 ni-mlx-8-port-10g-d
NOTE
This command pertains to the output of the command show running-config previously executed.
Removing module configuration requires power cycle of the module, to bring back the module to UP
state. Do you want to continue?
(enter 'y' or 'n'): y
Reset slot 2
device(config)#end
device#
device#show module
Module
M1 (left ):BR-MLX-MR2-M Management Module
M2 (right):NI-MLX-MR Management Module
F1:
F2: NI-X-HSF Switch Fabric Module
Brocade NetIron MLXe Series Hardware Installation Guide
53-1004203-04
Status
Ports
Starting MAC
Active
Standby(Ready State)
Active
Active
CARD_STATE_UP
4
0024.3887.3f00
CARD_STATE_UP
8
0024.3887.3f30
CARD_STATE_UP
8
0024.3887.3f60
CARD_STATE_UP
8
0024.3887.3f90
CARD_STATE_UP
8
0024.3887.3fc0
CARD_STATE_UP
20
0024.3887.3ff0
CARD_STATE_UP
8
0024.3887.4020
CARD_STATE_UP
4
0024.3887.4050
Status
Ports
Starting MAC
Active
Standby(Ready State)
Active
Active
CARD_STATE_UP
4
0024.3887.3f00
CARD_STATE_INTERACTIVE
CARD_STATE_UP
8
0024.3887.3f60
CARD_STATE_UP
8
0024.3887.3f90
CARD_STATE_UP
8
0024.3887.3fc0
CARD_STATE_UP
20
0024.3887.3ff0
CARD_STATE_UP
8
0024.3887.4020
CARD_STATE_UP
4
0024.3887.4050
Status
Ports
Starting MAC
Active
Standby(Ready State)
Active
Verifying proper operation
181

Advertisement

Table of Contents
loading

Table of Contents