Brocade Communications Systems NetIron MLXe Series Hardware Installation Manual page 222

Table of Contents

Advertisement

Managing interface modules
Specifying an immediate boot from flash memory on the interface module
To specify an immediate boot from the primary image in flash memory on the interface module installed in slot 1, enter the following
command at the Privileged EXEC level of the CLI.
device# lp boot system flash primary 1
Syntax: lp boot system flash [ primary | secondary ] slot-number
The primary and secondary keywords specify the primary or secondary image in the interface module flash memory.
The slot-number parameter specifies the slot number that contains the interface module that will undergo an immediate
boot.You can specify 1 - 4 for 4-slot devices, 1 - 8 for 8-slot devices, 1 - 16 for 16-slot devices, or 1 - 32 for 32-slot
devices.
Specifying an immediate boot from a TFTP server
To specify an immediate boot for the interface module installed in slot 1 from a TFTP server, enter the following command at the
Privileged EXEC level of the CLI.
device# lp boot system tftp 123.123.123.123 primary 1
Syntax: lp boot system tftp ip-addressfilenameslot-number
The ip-address parameter specifies the IP address of the TFTP server from which the interface module will be booted.
The filename parameter specifies the name of the image from which to boot the interface module.
The slot-number parameter specifies the slot number that contains the interface module that will undergo an immediate boot.
You can specify 1 - 4 for 4-slot devices, 1 - 8 for 8-slot devices, 1 - 16 for 16-slot devices, or 1 - 32 for 32-slot devices.
Specifying an immediate interactive boot
To specify an immediate interactive boot for the interface module installed in slot 1, enter the following command at the Privileged EXEC
level of the CLI.
device# lp boot system interactive 1
Syntax: lp boot system interactive slot-number
The slot-number parameter specifies the slot number that contains the interface module that will undergo an immediate boot.
You can specify 1 - 4 for 4-slot devices, 1 - 8 for 8-slot devices, 1 - 16 for 16-slot devices, or 1 - 32 for 32-slot devices.
After you enter this command, the system enters monitor mode on the interface module. To boot from the primary image in flash
memory on the interface module, enter the following command at the monitor prompt.
LP MONITOR> boot system flash primary
Configuring an automatic boot
To configure an automatic boot for one or all interface modules from a specified source, enter the lp boot system command in the global
CONFIG level. If you save this configuration by entering the write memory command, the system implements the automatic boot
starting with the next software reload or system reset and each reload or reset after that.
222
Brocade NetIron MLXe Series Hardware Installation Guide
53-1004203-04

Advertisement

Table of Contents
loading

Table of Contents