4.
Insert the new power supply into the empty power supply slot, using the guides provided on either side of the slot.
CAUTION
Carefully follow the mechanical guides on each side of the power supply slot and make sure the power supply is
properly inserted in the guides. Never insert the power supply upside down.
5.
After you insert the power supply, push gently on the power supply faceplate until the power supply is fully seated.
6.
Pull up on the handle on the power supply faceplate to lock the power supply in place.
7.
For a 4-slot device only, use the screwdriver to secure the two screws on either side of the power supply faceplate.
8.
For a 2400W DC power supply only, crimp the #4 AWG power supply wire in the power lugs.
9.
For a 3000W DC power supply only, crimp the #2 AWG power supply wire in the power lugs.
10. Connect the AC power cord or DC power lugs to the power supply faceplate.
11. Connect the power to the AC or DC source.
LEDs on the power supply faceplate show the status of the power supply with the following colors:
For a DC supply, the DC IN and DC OUT LEDs should be green, indicating the power supply is providing power to the
device components.
For an AC supply, the AC OK and DC OK LEDs should be green, indicating the power supply is providing power to the
device components (refer to the previous figure).
If the ALM LED is lit (amber), the power supply has failed.
For information about troubleshooting this problem, refer to

Replacing fan assemblies

You can replace a fan or a fan control module while the router is powered on and running. The fans and fan control modules are located
on the rear panel of the router.
NOTE
Fan trays are hot swappable. However, a hot-swap procedure should be completed within five minutes so the device will
continue to function correctly without any fans. It is recommended that you disconnect the power supply from AC or DC power
before installing or removing the fan tray.While fan assemblies are being replaced, and there is an increase or decrease in fan-
speed due to that, syslogs or console messages are not generated.

Replacing fan assemblies in all 32-slot routers

This section describes how to replace fan assemblies in MLXe 32-slot routers.
CAUTION
Removal of Brocade NetIron MLXe Series 32 rear fan modules allows access to bus bars and backplane. Avoid contact with
these parts. There are hazardous energy levels at these locations.
A 32-slot router has ten fan assemblies located at the rear of the router. They are numbered as indicated in the following figure.
You can remove and replace a fan assembly while the router is powered on and running.
NOTE
To avoid overheating of the router, remove one fan assembly at a time, and replace it promptly. Wait for the LED on the fan
assembly being replaced to turn green before replacing another fan assembly. Do not remove all fans from the device at once.
Brocade NetIron MLXe Series Hardware Installation Guide
53-1004203-04
Management module LEDs

Replacing fan assemblies

on page 31.