Replacing A Management Module; Installing The Compact Flash Card In An Mr2 Management Module - Brocade Communications Systems NetIron MLXe Series Hardware Installation Manual

Table of Contents

Advertisement

Replacing a management module

NOTE
The management, interface, and switch fabric modules are dedicated, which means that you must install them in Brocade
routers only. If you install these modules in another Brocade device or you install a module intended for another Brocade
device in a Brocade router, the device and modules will not function properly.

Replacing a management module

For instructions on how to install or replace modules, refer to the module installation section in the installation chapter for your router
model.

Installing the Compact Flash Card in an MR2 management module

MR2 management modules allow users to insert an additional 2 Gbps compact flash card. To install the card, you need a flat head or
Philips screw driver. Refer to the following figure to see where the slot card should be placed.
NOTE
MR and MR2 management modules should not be used together in the same chassis.Please read the Hardware Installation
Notes that came with your hardware before installing the MR2 management module.The internal compact flash card cannot be
accessed for removal or replacement.To obtain a replacement or a new compact flash card, contact Brocade technical support.
To install a compact flash card in an MR2 management module:
1.
Remove the two screws holding the compact flash card cover in place using a flat head or Phillips screw driver.
Put the screws and cover plate aside; you will need to reattach the cover using the screws after installing the card.
2.
Slide the compact flash card into the slot.
246
Brocade NetIron MLXe Series Hardware Installation Guide
53-1004203-04