PBIF Recovery
In the event PBIF gets locked up, PBIF recovery is activated by default with the option to activate PBIF recovery through the
system-monitoring pbif lp-reset-recovery command.
Syntax
system-monitoring pbif lp-reset-recovery
no system-monitoring pbif lp-reset-recovery
Command Default
PBIF is locked up.
Examples
In the event PBIF is locked up, PBIF recovery is activated by default. However, if necessary you may activate PBIF recovery
through the system-monitoring pbif lp-reset-recovery command.
device# config
device(config)# system-monitoring pbif lp-reset-recovery
device(config)# exit
device# write memory
device# reload
To deactivate PBIF recovery perform the no system-monitoring pbif lp-reset-recovery command.
device# config
device(config)# no system-monitoring pbif lp-reset-recovery
device(config)# exit
device# write memory
device# reload
History
Release version
5.7.00
2x100GbE CFP2 P2010 specifications
P2010 specifications are shown for the 2x100GbE CFP2 optics based high density blade.
TABLE 11 2x100GbE CFP2 P2010 Specifications
Component
Processor
Processor Version
System Version
Core Version
Clock Speed
Cache Support
Brocade NetIron MLXe Series Hardware Installation Guide
53-1004203-04
Command history
This command was introduced.
Gen 2 Cards
MPC8548E
0x8021_0022
0x8031_0021
E500V2
1.3GHz
32KB L1 instruction cache
32KB L1 data cache
2x100GbE CFP2 Cards
P2010
0x8021_1051
0x80e3_0021
E500V2
1.2Ghz
32KB L1 instruction cache
32KB L1 data cache
Router modules