Managing the cooling system
threshold for the high speed, the router shuts down the modules to prevent damage. The router also sends a warning message
to the system log and an SNMP trap. For information about viewing the warning messages, refer to
warnings
on page 218.
The frequency with which the temperature is checked is determined by the setting of the temp-poll-period command. For
information about temp-poll-period command, refer to
If the temperature of a management module, switch fabric module, and interface modules falls below the low threshold for a fan
speed, the fan changes to the next lower speed. If the temperature of all modules falls below the high threshold for the low
speed, the fan operates at the low speed.
Default temperature thresholds for Brocade NetIron MLX Seriesdevices are described in the following table.
TABLE 42 Default temperature thresholds for modules and fan speeds for Brocade MLXe devices
Fan speed
Management modules
High
Medium-high
Medium
Low
Management modules CPU
High
Medium-high
Medium
Low
Interface modules
High
Medium-high
Medium
Low
Interface modules Packet Processor
High
Medium-high
Medium
Low
Generation 2 Interface modules
High
Medium-high
Medium
Low
Generation 2 Interface modules Packet Processor
High
Medium-high
Medium
Low
Switch fabric module
High
212
Changing the temperature polling interval
Low temperature threshold
72 ° C
67 ° C
52 ° C
-1 °
72 ° C
65 ° C
63 ° C
-1 °
65 ° C
63 ° C
61 ° C
-1 °
77 ° C
72 ° C
69 ° C
-1 °
70 ° C
62 ° C
58 ° C
-1 °
74 ° C
70 ° C
66 ° C
-1 °
47 ° C
Displaying temperature
on page 216.
High temperature threshold
85 ° C
80 ° C
70 ° C
60 ° C
95 ° C
80 ° C
74 ° C
70 ° C
95 ° C
81 ° C
79 ° C
74 ° C
113 ° C
94 ° C
92 ° C
90 ° C
95 ° C
80 ° C
75 ° C
70 ° C
113 ° C
87 ° C
85 ° C
83 ° C
75 ° C