Brocade Communications Systems NetIron MLXe Series Hardware Installation Manual page 215

Table of Contents

Advertisement

state = 0 (FAN_STATE_LOW)
max_ts_shut_off_count = 1
shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
The output displays the following information.
TABLE 43 Temperature threshold information for modules and fan speeds
This field...
Thermal Sensor Control Block
(THERMAL_SENSOR_TEST_RULE_module)
Fan Speed Low or Med or Med-Hi or Hi
State = 0 (FAN_STATE_LOW)
max_ts_shut_off_count
shut_off_count = 0 0 0 0 0 0 0 0
When syslog messages display a change in fan speed, you can identify which sensors triggered the change by checking show chassis
and show fan-threshold command output and looking for sensors with temperatures near threshold boundaries. The following table lists
the associations between the show chassis , show fan-threshold , and fan-threshold commands .
NOTE
A "thermal block" refers to the group of high and low thresholds for all fan speed levels.
TABLE 44 Associations between show chassis, show fan threshold, and fan-threshold commands
show chassis command output (sensors)
MP, SFM, and hSFM Modules
Active Management 1st reading
Active Management 2nd reading
Standby Management 1st reading
Standby Management 2nd reading
SFM FE1 reading
SFM FE2 reading
SFM FE3 reading
hSFM FE1 reading
hSFM FE2 reading
hSFM FE3 reading
Brocade NetIron MLXe Series Hardware Installation Guide
53-1004203-04
Displays...
The temperature threshold information for the various modules. The
module parameter indicates the following:
The current setting of the low and high temperature thresholds for the low,
medium, medium-high, and high fan speeds.
For Brocade internal use only.
For Brocade internal use only.
For Brocade internal use only.
show fan-threshold command output (thermal
block)
THERMAL_SENSOR_TEST_RULE_MP
THERMAL_SENSOR_TEST_RULE_MP_CPU
THERMAL_SENSOR_TEST_RULE_STANDBY
_MP
THERMAL_SENSOR_TEST_RULE_STANDBY
_MP_CPU
THERMAL_SENSOR_TEST_RULE_SNM
THERMAL_SENSOR_TEST_RULE_SNM
THERMAL_SENSOR_TEST_RULE_SNM
THERMAL_SENSOR_TEST_RULE_SNM_G2
THERMAL_SENSOR_TEST_RULE_SNM_G2
THERMAL_SENSOR_TEST_RULE_SNM_G2
MP - The active management module
STANDBY_MP - The standby management module
SNM - The switch fabric module
LP - An interface module
NOTE
As indicated in
Table
44, the low fan speed for each module
does not have a default low temperature threshold value, nor
can you configure this value. The "-1" value that appears in the
Fan Speed Low field for each module is a Brocade internal
value only.
fan-threshold command configuration
fan-threshold mp
fan-threshold mp-cpu
fan-threshold mp
fan-threshold mp-cpu
fan-threshold switch-fabric
fan-threshold switch-fabric
fan-threshold switch-fabric
fan-threshold switch-fabric-g2
fan-threshold switch-fabric-g2
fan-threshold switch-fabric-g2
Managing the cooling system
215