Foundry Hardware Installation Guide for the NetIron CES 2000 Series
NOTE: The socket should be installed near the equipment and should be easily accessible.
NOTE: If the outlet is not rated 115/120V, stop and get the appropriate cable for the outlet.
WARNING: The intra-building port(s) of the equipment or subassembly is suitable for connection to intra-building
or unexposed wiring or cabling only. The intra-building port(s) of the equipment or subassembly MUST NOT be
metallically connected to interfaces that connect to the OSP or its wiring. These interfaces are designed for use as
intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 4) and require isola-
tion from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to con-
nect these interfaces metallically to OSP wiring.
WARNING: Before crimping the ground wire into the provided ground lug insure the bare copper wire has been
cleaned and antioxidant is applied to the bare wire.
WARNING: To insure adequate bonding when attaching the ground lug, a minimum of 20 PSI of torque is
required to be applied to the mounting hardware used to attach the ground lug."

Verifying Proper Operation

After you have installed any redundant power supplies, verify that the device is working properly by plugging it into
a power source and verifying that it passes its self test.
If your device has more than one power supply installed, repeat this procedure for each power supply.
1.
Connect the power cord supplied with the device to the power connector on the power supply on the rear of
the device.
2.
Insert the other end into a properly grounded electrical outlet.
3.
Verify that the LED for each power supply is a solid green.
4.
Verify proper operation by observing the LEDs:
All the port LEDs should flash momentarily, usually in sequence, while the device performs diagnostics. After
the diagnostics are complete, the LEDs will be dark except for the ones that are attached by cables to other
devices. If the links on these cables are good and the connected device is powered on, the link LEDs will light.

Observing the Power Status LEDs

Table 3.2 lists the LEDs that show power status. The power supplies themselves do not have LEDs.
LEDs for Power and Fan Status for the NetIron CES 2024 Models
Table 3.2: LEDs for Power and Fan Status for the CES 2024 Models
LED
Fan (labeled fn)
3 - 14
Position
State
Right side of
On
front panel
Off
© 2009 Brocade Communications Systems, Inc.
Meaning
The fan tray is powered on and is
operating normal.
The fan tray is not powered on, or has
been removed.
March 2009