Figure 50: Recommended Positions of the Modules in the Rack for Scale
a. Server module on the highest (Variant 2) or lowest position (Variant 1).
b. Storage base module directly under or above it
c. All storage expansion modules directly under or above the storage base module.
CAUTION!
The DX100 S3 storage expansion modules are preconfigured and assigned by
numbers in the factory. This sequence must be observed precisely when they are
mounted. Otherwise the system does not work.
The labels with the numbers assigned in the factory are affixed at the right flange of
the front side and at the ID card on top of the cover as described in figure
Front and Rear of the Storage Expansion Module" on page
The table below shows the numbering schemes for the storage array(s).
Storage Modules
DX100 S3 base
1 DX100 S3 expansion module on the DX100 S3 base
2 DX100 S3 expansion module on the DX100 S3 base
3 DX100 S3 expansion module on the DX100 S3 base
...
10th DX100 S3 expansion module on the DX100 S3 base
Table 21: Numbering of the Storage Modules for a Scale System
ETERNUS CS800
5.1 Locating the Mounting Position
"Labels on
77.
Denotation
CE
DE-1
DE-2
DE-3
...
DE-a
79