CAUTION!
The server is automatically set to a mains voltage in the range 100 V - 240 V.
You may only operate the server if its rated voltage range corresponds to the
local mains voltage.
Connect the power cord with the insulated connector to the power supply unit of the
server, and plug the power plug into a grounded outlet on the mains socket strip on
the rack (see Technical Manual of the rack).
A phase redundancy in the power supply of the server can be set up if each of
the power supply units is either connected to two different phases or to two
separate circuits of the internal power supply network.
Using the cable clamp
You can secure the power cords in a cable clamp to ensure that the insulated connectors
cannot be disconnected from the server accidentally.
Figure 12: Cable clamp
1. Pull the cable clamp up (2).
2. Thread the power cord through the cable clamp (1).
3. Press the cable clamp down until it engages to secure the cable (3).