5

Installing the ETERNUS CS800 S6 Modules

It is recommended to install the ETERNUS CS800 system in a controlled or
restricted area to prevent access by untrained personnel. In addition, it is
recommended that system installation is performed only by qualified IT
personnel.
Installing the ETERNUS CS800modules in a rack consists of the following steps:
1.
"Locating the Mounting Position" on page 77
2.
"Installing the components in the rack" on page 80
3.
"Cabling the ETERNUS CS800 S6 System" on page 87
Necessary tools
Provide the following tools for unpacking and installing the ETERNUS CS800 system:
#2 Phillips and Torx 20 screwdriver
l
Taking ESD precautions
Some components within the ETERNUS CS800 system contain static-sensitive parts. To
avoid damaging these parts while performing installation procedures, always observe the
following precautions:
Keep the system turned off during all installation procedures.
l
Keep static-sensitive parts in their original shipping containers until ready for
l
installation.
Do not place static-sensitive parts on a metal surface. Place them inside their
l
protective shipping bag or on an antistatic mat.
Avoid touching connectors and other components.
l
Dry climates and cold-weather heating environments have lower relative
humidity and are more likely to produce static electricity.
CAUTION!
Do NOT discard the packing materials after the system is unpacked. The packaging
materials must be used if the system is relocated.
WARNING!
The server PRIMERGY RX2540 M1 weighs 25 kg (55 lbs). The storage module
ETERNUS JX40 S2 weighs 35 kg (77 lb). Also the controller enclosure and each drive
enclosure of the ETERNUS DX100 S3 weighs 35 kg (77 lb). Two people are required
to lift either chassis.
ETERNUS CS800