Fujitsu ETERNUS CS800 S6 User Manual page 59

Hide thumbs Also See for ETERNUS CS800 S6:
Table of Contents

Advertisement

Figure 31:
Figure 32: Rear view of JX40 S2- I/O module
LED name
SAS IN link
SAS IN fault
SAS OUT link green
SAS OUT fault amber
READY LED
IDENTIFY LED blue
FAULT LED
Table 10: Status and meanings of each LED (I/O module)
Power Supply Units
The power supply unit transforms input AC power from a power socket to DC power and
supplies power to each component.
Each power supply unit contains fans.
ETERNUS CS800
LED status Description
green
The link between the SAS IN port and the source port has been
established.
amber
The ports to remove the mini SAS HD cables between
enclosures from are indicated. This occurs while a drive
enclosure is being added.
The link between the SAS OUT port and the destination port has
been established.
The link between the SAS OUT port and the destination port is
in error status.
green
The I/O module is in normal status.
Identifies the installation location of the I/O module.
amber
The I/O module is in error status.
3.2 Storage Modules
59

Hide quick links:

Advertisement

Table of Contents
loading