Fujitsu ETERNUS CS800 S6 User Manual page 256

Hide thumbs Also See for ETERNUS CS800 S6:
Table of Contents

Advertisement

CAUTION!
For encryption, select None or 128-bit if you are sending data to a ETERNUS
CS800 running a system software version prior to ETERNUS CS800 2.1.1 software.
AES encryption options are available only if the Data-in-Flight license is
installed.
4. In the Source IP Address box, enter the IP address that is used to uniquely identify the
source ETERNUS CS800 to the target. This may be different than the actual network IP
address of the source ETERNUS CS800.
If the target system is at ETERNUS CS800 2.1 software higher, the Source IP Address
field is not required. If the target system is at ETERNUS CS800 2.0.1 software or below,
then you must enter the IP address by which the target system recognizes the source
system. The default value is 0.0.0.0.
The Source IP Address field does not accept fully qualified domain names.
You must enter a valid IP address. Make sure this IP address is configured in
the allowable sources list on the target ETERNUS CS800.
When configuring segmented network interfaces, if the source ETERNUS
CS800 replication, data, and management interfaces are on the same
subnet, you must add a host route on the source ETERNUS CS800 to make
sure the replication interface is correctly selected when replicating data to
the target ETERNUS CS800 (see
304).
5. Click Apply.
6. Under Target System, select the target and click Resume to pause replication.
ETERNUS CS800
"Understanding Interface Routing" on page
10.5 Replication Configuration
256