GE P4A Technical Manual page 733

Micom p40 agile single br eaker multi-end current differential ied (non distance)
Table of Contents

Advertisement

P54A/B/C/E
MENU TEXT
A map of the terminals and junctions in the system for P541 only
Length Local
Length of the local terminal section in KM
Length Local
Length of the local terminal section in miles
Length J1-J2
Distance between junction 1 and 2 when it is a mult-junction network in KM
Length J1-J2
Distance between junction 1 and 2 when it is a mult-junction network in KM
Length J2-J3
Distance between junction 2 and 3 when it is a multi-junction network in KM
Length J2-J3
Distance between junction 2 and 3 when it is a multi-junction network in KM
Length J3-J4
Distance between junctions 3 and 4 when it is a multi-junction network in KM
Length J3-J4
Distance between junctions 3 and 4 when it is a multi-junction network in KM
Line Type Local
This setting is used to select the overhead line or the underground cable. If it is overhead line, the admittance parameters will be invisiable,
they will be deduced via fomular
Z1Local
Positive sequence impedance amplitude of the local section length per KM
Z1LocalAngle
Positive Sequence impedance angle of the local section length
Z0Local
Zero Sequence impedance amplitude of the local section length
Z0LocalAngle
Zero Sequence impedance angle of the local section length
Y1Local
Positive sequence admittance amplitude of the local section length (the conductance is neglected)
Y0Local
Zero sequence admittance amplitude of the local section length (the conductance is neglected)
Line Type J1-J2
This setting is used to select the overhead line or the underground cable. If it is overhead line, the admittance parameters will be invisiable,
P54xMED-TM-EN-1
COL
ROW
DEFAULT SETTING
30
22
45000
30
23
28000
30
24
100000
30
25
62.1
30
26
100000
30
27
62.1
30
28
100000
30
29
62.1
30
2A
UnderGndCable
30
2B
8
30
2C
70
30
2D
8
30
2E
70
30
2F
0.00000001*I1
30
30
0.00000001*I1
30
31
UnderGndCable
DESCRIPTION
T6 J3
T1 J4
T2 J4
T3 J4
T4 J4
T5 J4
T6 J4
[Binary Flag (24) & Indexed String]
From 100 to 10000000 in steps of 10
[Courier Number (metres)]
From 0.06 to 621 in steps of 0.005
[Courier Number (miles)]
From 100 to 10000000 in steps of 10
[Courier Number (metres)]
From 0.06 to 621 in steps of 0.005
[Courier Number (miles)]
From 100 to 10000000 in steps of 10
[Courier Number (metres)]
From 0.06 to 621 in steps of 0.005
[Courier Number (miles)]
From 100 to 10000000 in steps of 10
[Courier Number (metres)]
From 0.06 to 621 in steps of 0.005
[Courier Number (miles)]
OverheadLine
[Indexed String]
From 0.05*v1/I1 to 500*V1/I1 in steps of 0.01*V1/I1
[Courier Number (impedance)]
From 0 to 10 in steps of 0.01
[Courier Number (angle)]
From 0.05*v1/I1 to 500*V1/I1 in steps of 0.01*V1/I1
[Courier Number (impedance)]
From 0 to 10 in steps of 1
[Courier Number (angle)]
From 0.00000001*I1 to 10*I1 in steps of
0.00000001*I1
[Courier Number (inverse ohms)]
From 0.00000001*I1 to 10*I1 in steps of
0.00000001*I1
[Courier Number (inverse ohms)]
OverheadLine
[Indexed String]
Appendix B - Settings and Signals