GE P4A Technical Manual page 765

Micom p40 agile single br eaker multi-end current differential ied (non distance)
Table of Contents

Advertisement

P54A/B/C/E
MENU TEXT
SP AR Dead Time
Dead time setting for single phase auto-reclose.
3P AR DT Shot 1
Dead time setting for three phase auto-reclose (first shot).
3P AR DT Shot 1
Dead time setting for three phase auto-reclose (first shot).
3P AR DT Shot 2
Dead time setting for three phase auto-reclose (2nd shot).
3P AR DT Shot 2
Dead time setting for three phase auto-reclose (2nd shot).
3P AR DT Shot 3
Dead time setting for three phase auto-reclose (3rd shot).
3P AR DT Shot 3
Dead time setting for three phase auto-reclose (3rd shot).
3P AR DT Shot 4
Dead time setting for three phase auto-reclose (4th shot).
Follower Time
Time delay setting for follower CB reclosing after leader CB has reclosed.
SPAR ReclaimTime
Reclaim time setting following single phase auto-reclosure.
SPAR ReclaimTime
Reclaim time setting following single phase auto-reclosure.
3PAR ReclaimTime
Reclaim time setting following three phase auto-reclosure.
3PAR ReclaimTime
Reclaim time setting following three phase auto-reclosure.
3PAR ReclaimTime
Reclaim time setting following three phase auto-reclosure.
AR CBHealthyTime
Settable time delay for autoreclosure with this circuit breaker check. If the circuit breaker does not indicate a healthy condition in this time
period following an auto close command then the IED will lockout and alarm. CB Healthy is required for manual and auto reclosures.
Z1 AR
Setting that determines impact of instantaneous zone 1 on AR operation. Set Initiate AR if the trip should initiate a cycle, and Block AR if an
instantaneous zone 1 trip should cause lockout. (Only in models with distance option)
Phase Comp AR
Setting that determines impact of the phase comparison tripping on AR operation.
Dist Aided AR
Setting that determines impact of the aided distance schemes tripping on AR operation.
(Only in models with distance option)
P54xMED-TM-EN-1
COL
ROW
DEFAULT SETTING
49
67
0.5
49
68
0.3
49
68
0.3
49
69
60
49
69
60
49
6A
60
49
6A
60
49
6B
60
49
6C
5
49
6D
60
49
6D
60
49
6E
180
49
6E
180
49
6E
180
49
6F
5
49
72
Initiate AR
49
73
Initiate AR
49
74
Initiate AR
DESCRIPTION
From 0 to 10 in steps of 0.01
[Courier Number (time-seconds)]
From 0.01 to 300 in steps of 0.01
[Courier Number (time-seconds)]
From 0.01 to 300 in steps of 0.01
[Courier Number (time-seconds)]
From 1 to 9999 in steps of 1
[Courier Number (time-seconds)]
From 1 to 9999 in steps of 1
[Courier Number (time-seconds)]
From 1 to 9999 in steps of 1
[Courier Number (time-seconds)]
From 1 to 9999 in steps of 1
[Courier Number (time-seconds)]
From 1 to 9999 in steps of 1
[Courier Number (time-seconds)]
From 0.1 to 300 in steps of 0.01
[Courier Number (time-seconds)]
From 1 to 600 in steps of 1
[Courier Number (time-seconds)]
From 1 to 600 in steps of 1
[Courier Number (time-seconds)]
From 1 to 600 in steps of 1
[Courier Number (time-seconds)]
From 1 to 600 in steps of 1
[Courier Number (time-seconds)]
From 1 to 600 in steps of 1
[Courier Number (time-seconds)]
From 0.01 to 9999 in steps of 0.01
[Courier Number (time-seconds)]
Initiate AR
Block AR
[Indexed String]
Initiate AR
Block AR
[Indexed String]
Initiate AR
Block AR
[Indexed String]
Appendix B - Settings and Signals
AVAILABLE OPTIONS
B199

Advertisement

Table of Contents
loading

This manual is also suitable for:

P54bP54eP54c

Table of Contents